Permit: T02CM04534

Parcel: 120030910


Addresses:

825 W COLUMBIA ST

Inspection Status: Approved

Inspection History: ROOF NAILING

Date Description Inspector Results Comments
07/03/2003 ROOF NAILING Approved IVRS - Inspection 0000*
07/01/2003 ROOF NAILING Denied IVRS - Inspection 0999* 1)PERLING MUST BE SUPPORTED WITH U-24 HANGERS ON EACH END WITH ALL PERLING INSTALLED VIRTUALLY NOT IN THE FLAT. 2) ROOF SHEATHING MUST BE NAILED TO PERLING. 3) TRUSS DRAWINGS MUST BE APPROVED BY CITY OF TUCSON. 4) 4 X 12 BEAM MUST BE SECURED BY 1/2" BOLTS.
06/27/2003 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) NEED TRUSS DRAWINGS AND LAYOUT SHEET
06/17/2003 ROOF NAILING Denied IVRS - Inspection 0999*/ 1) ANCHOR BOLTS REQUIRED WITHIN 12" OF PLATE SPLICES AND ENDS 2) GLUE LAM BEAM NOT IN TO SUPPORT AT BAY WINDOW 3) NAIL DOUBLED TRUSSES AT 12" ON CENTER TOP AND BOTTOM CHORD 4) 1" SEPARATION REQUIRED BETWEEN PORCH POST AND CONCRETE 5) OVER SPAN AT FIREPLACE PROVIDE TRUSS PLANS
06/04/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHEATHING MISSING AT ROOF
05/27/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*
03/24/2003 ROOF NAILING Not ready for Inspection IVRS - Inspection 0000*