Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM04493
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/12/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/07/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | 1) RENAIL REAR SHEAR PANEL NUMEROUS NAILS NOT PROPERLY PENETRATING STUDS 2) NAIL TRUSS AND PANELS AT GARAGE SHEAR W/#8 AT 6" ON CENTER GET ENGINEER OF RECORD TO CLARIFY NAILING SCHEDULE ON THIS WALL SEE DT1/10 AND 14 |