11/04/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
11/01/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) PROVIDE 2 KING STUDS AT OPENINGS GREATER THAN 2' PER PLAN 2) PLAN CALLS FOR 2 X 8 RAFTERS AT PATIO 3) CLIP ENTRY HDR. AND STUDS 4) GARAGE OPENING REQUIRES 3 KING STUDS PER PLAN 5) L-50'S MISSING AT LEDGER GARAGE SEPERATION WALL |