Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 12/20/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 12/17/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GARAGE SHEAR REQUIRES TIGHT CS-16 STRAPS TO 2 DOUBLE STUDS TO GLU LAM BEAM |
| 12/12/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) PROVIDE AN ENGINEERS AND CITY OF TUCSON APPROVED DRAWING FOR SHEAR WALL 6 CONNECTION TO 2ND FLOOR JOIST AND GLUE LAM BEAM TO FLOOR CONNECTION PAGE A2-3. FAILURE TO PROVIDE APPROVED DRAWING/DETAIL WILL BE CHARGE A REINSPECTION FEE |
| 12/10/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) WEST WALL SHEAR STRAPS AND STUDS NOT PER PLAN. SHIM FLOOR 2) NAIL PROTECT ALL PLUMBING WITHIN 1 1/4" OF WALL SURFACE 3) HAVE ENGINEER OF RECORD PROVIDE DETAIL OF HOW TO COMPLY WITH HOLDOWN SCHEDULE 4) HAVE ENGINEER PROVIDE DETAIL OF ALL POST TO BEAM CONNECTIONS 5) HIP HANGER MISSING 6) POST FROM ROOF TO GROUND |
| 12/06/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0950*/ 1) SHEAR WALL NOT NAILED PER PLAN 2) SHEAR WALL NAILS DRIVEN TO DEEP 3) GABLE END TRUSS NOT CONNECTED/NAILED TO SHEARWALL 4) CS 16 STRAPS NOT INSTALLED PER PLAN OR SIMPSON REQUIREMENTS 5) 2ND FLOOR NOT FULL BEARING WEST WALL 6) NO LADDER ACCESS TO ROOF 7) NO TRUSS CALCULATIONS 8) SHEAR WALLS NOT NAILED PER PLAN, SUPERINTENDENT TO INSURE TRADES HAVE BUIL TO PLAN AND CODE PRIOR TO NEXT INSPECTION FAILURE TO DO SO WILL BE CHARGED A REFEE |
| 12/02/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Not ready for Inspection |
IVRS - Inspection 0000* |