Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/13/2002 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 11/12/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CHANGE FURNACE FLUE HORIZONTAL RUN |
| 11/06/2002 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) CORRECT NEGATIVE PITCH OF FLUE AT ROOF 2) SHIM HEADERS WHERE NEEDED 3) NOT ENOUGH WATER FOR DWV-REPEAT |
| 11/06/2002 |
FRAMING |
|
Denied |
1) PROVIDE CONTINOUS 2 X BLOCKING AT MID SPAN OF GABLE 2) END HINGE BRACING PER DT1/6 3) GARAGE SHEARWALL NO 6 REQUIRES A35'S EACH 12" FROM TRUSS BOTTOM CHORD TO DOUBLE TOP PLATE. PER DT1/10 AND TOE NAIL W/16D'S AT 12" ON CENTER 4) STRAP GAS PIPING TO TRUSS CHORDS. RE-ALIGN GAS PIPING ABOVE MASTER BEDROOM SO IT RESTS ON TRUSS BOTTOM CHORD |