Permit: T02CM04359

Parcel: 220110740


Addresses:

11100 N ORACLE RD

Inspection Status: Partial Approval

Inspection History: FRAMING

Date Description Inspector Results Comments
02/07/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) WILL RE-INSPECT INTERMEDIATES AT PERMANENT SITE 2) NO GAS IN HOUSE AS PER KIRBY (SUPER)
02/06/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) DOUBLE TOP PLATE AT MASTER CLOSET OVER NOTCHED REQUIRES STRAPS IN 6 EACH 16D NAILS ON EACH SIDE 2) WATER LINES AND DWV'S NO TEST 3) PROTECT ALL PLUMBING WITHIN 1 1/2 FROM EDGES OF STUDS 4) EXHAUST FAN IN HALL BATH NOT CONNECTED TO EXHAUST LINE 5) GAS LINE NOT INSTALLED 6) SEE PREVIOUS INSPECTIONS
01/30/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) PLUMBING FOR RE-VENTING PURPOSE TEE'S MUST BE INSTALLED WITH SWEEP GOING UP (WOULD BE UPSIDE DOWN FOR DRAIN) 2) A. ELECTRIC-MAKE UP ALL GROUNDS IN ALL BOXES B. METAL CEILING BOXES MUST BE GROUNDED 3) PRESSURE TEST WATER AND DWV SYSTEMS 4) MECHANICAL REGISTERS MUST BE SUPPORTED ON 3 SIDES 5) EXTEND ELECTRIC HOME RUNS INTO MAIN PANEL 6) INSTALL GAS LINES AND PROVIDE PRESSURE TEST
01/28/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) ALL OTHER TRADES, PLBG, ELECT, AND MECH SHALL BE COMPLETED PRIOR TO FRAME INSPECTION 2) STAPLE LATH AT 6" ON CENTER TOP AND BOTTOM EDGE