Permit: T02CM04330

Parcel: 141302290


Addresses:

10532 E MALTA ST

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/28/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/24/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PROVIDE CLIPS AT BUILT UP WALL, GARAGE AND ENTRY 2) PROVIDE 2 X BLOCKAGE AT GABLE END BRACE LOCATIONS ALSO MISSING A-34 PER PLAN 3) PROVIDE BRACING AT GABLE END IN GARAGE PER PLAN 413/SD 4) PROVIDE 2 X BLOCKAGE AT RIDGE BOARD BETWEEN TRUSSES SEE 411/SD 5) HAVE ARCHITECT OF RECORD PROVIDE CLARIFICATION ON CONNECTIONS AT REAR PATIO PARAPET WALL 6) CHECK EDGE NAILING AT PERIMETER ON ROOF