Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04292

Parcel: 13632002Q


Addresses:

4094 S MELPOMENE WY

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
06/09/2003 FRAMING Approved IVRS - Inspection 0000*
06/06/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) GAP IN FIRE BLOCKS HALL SIDE OF KITCHEN SOFFIT TOE NAIL 2) FIX ALL STUDS CUT AT DIAGONAL TO STRAIGHTEN 3) STILL MISSING FAN DAMPERS 4) HALL CEILING CAN LIGHT MOVE PEX, OPPOSITE KITCHEN 5) DINING ROOM, KITCHEN STUD OVER SPAN MARKED ON FLOOR 6) LOCATE AT TERMINATION, CONDENSATE, TPR FOR GARAGE AC/#20 HTR 6) SHEARWALL BOLT PATTERN, SHOUT DOWN JOINTS 7) COULDN'T FIND PLAN, OR PERMIT 8) MISSED AT LAST INSP. FLEXIBLE GAS LINE WARD FLEX NEED TO SEE AND DEMAND CHART FROM MANUFACTURE 1" FLEX NOT EQUAL TO 1" FROM DELIVERY, REQUIRED FOR SECURING AND INSTALLING
06/04/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) ROMEX OUT OF WALL ENTERTAINMENT AREA 2) FIX CUT STUD POOL BATH 3) OVERSPAN STUDS KITCHEN 4) BANG PLATE ROMEX KITCHEN SOUTH OF PONY WALL 5) CHECK ALL DAMPERS EXHAUST 6) MOVE ALL PEX 12" AWAY FROM L/CAN 7) NEED POSITIVE PITCH ON 2" VTR, SOUTH BATH 8) WEST BATH SECURE BANG PLATE AT TUB, CONCRETE BLOCK OUTS IN FLOORS 9) TIGHTEN ALL A.B. FOR H.D. 10) NEED A.B. FOR SW1 SHEARWALLS
06/02/2003 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) COMPLETE NAILING ALL LATH