Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 06/09/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 06/06/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) GAP IN FIRE BLOCKS HALL SIDE OF KITCHEN SOFFIT TOE NAIL 2) FIX ALL STUDS CUT AT DIAGONAL TO STRAIGHTEN 3) STILL MISSING FAN DAMPERS 4) HALL CEILING CAN LIGHT MOVE PEX, OPPOSITE KITCHEN 5) DINING ROOM, KITCHEN STUD OVER SPAN MARKED ON FLOOR 6) LOCATE AT TERMINATION, CONDENSATE, TPR FOR GARAGE AC/#20 HTR 6) SHEARWALL BOLT PATTERN, SHOUT DOWN JOINTS 7) COULDN'T FIND PLAN, OR PERMIT 8) MISSED AT LAST INSP. FLEXIBLE GAS LINE WARD FLEX NEED TO SEE AND DEMAND CHART FROM MANUFACTURE 1" FLEX NOT EQUAL TO 1" FROM DELIVERY, REQUIRED FOR SECURING AND INSTALLING |
| 06/04/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ROMEX OUT OF WALL ENTERTAINMENT AREA 2) FIX CUT STUD POOL BATH 3) OVERSPAN STUDS KITCHEN 4) BANG PLATE ROMEX KITCHEN SOUTH OF PONY WALL 5) CHECK ALL DAMPERS EXHAUST 6) MOVE ALL PEX 12" AWAY FROM L/CAN 7) NEED POSITIVE PITCH ON 2" VTR, SOUTH BATH 8) WEST BATH SECURE BANG PLATE AT TUB, CONCRETE BLOCK OUTS IN FLOORS 9) TIGHTEN ALL A.B. FOR H.D. 10) NEED A.B. FOR SW1 SHEARWALLS |
| 06/02/2003 |
FRAMING |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) COMPLETE NAILING ALL LATH |