Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04292

Parcel: 13632002Q


Addresses:

4094 S MELPOMENE WY

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
05/09/2003 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*/ 1) PORCH AT POOL ADD H2.5'S AT 4'-0" AND A3.5'S INSIDE OF LEDGER USE 8D'S
04/17/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) OK ALL LEDGER CLIPS OK TO COVER