Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04290
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/06/2003 | FRAMING | Approved | IVRS - Inspection 0000* | |
12/26/2002 | FRAMING | Denied | IVRS - Inspection 0999* CONTINUE WITH ABOVE CORRECTIONS 4/5O4 MUST BE 2"X4'' BLOCKING ALL AROUND EA CAVITY COMPLETE 18/504 | |
12/20/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
12/19/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) BEFORE YOU LATH ANY FURTHER INSTALL PLYWOOD BAND AT FLOOR TRUSSES PER DETAIL 2/SD2 THIS IS TYPICAL FOR ALL YOUR 2 EAST/WEST WALLS, STONY HOUSE 1/SD2 FOR ALL PERPENDICULAR FLOOR TRUSSES REARWALL AND FRONT WALL AT STAIR WELL, CONTINOUS TIE REQUIRED, I WILL BE HERE TOMORROW TO EXPLAIN,SEE CIRCLE ON S-2 2) EXHAUST FAN DAMPERS MISSING BOTH FANS 1ST FLOOR 3) BETWEEN FLOOR BLOCKS AT TRUSS INTERIOR BEARING PT. 4) 16D COMMON NAILS AT GIRDER TO TRUSS HANGER 5) FINISH CONDENSATE LINES 6) A/C LINE SETS FHA STRAP AND ADD STUD UNDER TRUSS DOUBEL TOP PLATE CUT 7) FIRE STOP AT WATER HEATER FLUE PENETRATION, CEILING 8) SECURE PEX AT TOILET, BANG PLATE AT BOTTOM PLATE 9) NEED WIND BRACE AT SOUTH EAST GORNER FRONT 2ND FLOOR 10) BETWEEN BEDROOM 4 AND BATH SHEARWALL TO BE G1 WITH DOUBLE TOP PLATE, INSTALL PANELS PER 4/SD4 PANELS NOT BUILT CORRECTLY, THEY ARE NOT NAILED TO THIS ROOF DECK 11) 2ND FLOOR INTERIOR SHEARWALL BOTTOM PLATE EACH END OF EALL ATTACH PER 18/SD4 12) MISSING LATERAL BRACES ON MAIN GABLE TRUSS | |
12/17/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) STOPPED BY SUPERINTENDENT |