Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/18/2003 FRAMING Approved IVRS - Inspection 0000*
02/14/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) COMPLY WITH DETAIL 2 DT1 AS ADVISED ON ALL OTHER UNITS
02/13/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) ALL ITEMS NOT CORRECTED 2) COMPLETE SHEAR TRANSFER AT GARAGE PER DETAIL E-1
02/12/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) BLOCK MECHANICAL IN LAUNDRY ROOM OK TO INSULATE AND SHEET ROCK, EXCEPT THIS AREA
02/11/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) MECHANICAL NOT BLOCKED IN LAUNDRY ROOM 2) NAIL PROTECT WIRSBO LINE FOR FRIDGE LIVING ROOM SIDE 3) NAIL PROTECT WIRSBO LINES IN KITHCEN WITHIN 1 1/2 FROM EDGE OF STUD 4) FIREBLOCK FURRED OUT SPACE IN LIVING ROOM WHERE COPPER LINES COME IN OVER DOUBLE TOP PLATE 5) BLOCK ALL MECHANICAL ON 3 SIDES 6) COMPLY WITH DETAIL 10/DT1 7) DWV'S WATER TEST PASSED, PARTIAL ON PLUMBING UNTIL #2 AND #3 ARE DONE