Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/18/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/14/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) COMPLY WITH DETAIL 2 DT1 AS ADVISED ON ALL OTHER UNITS |
| 02/13/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) ALL ITEMS NOT CORRECTED 2) COMPLETE SHEAR TRANSFER AT GARAGE PER DETAIL E-1 |
| 02/12/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) BLOCK MECHANICAL IN LAUNDRY ROOM OK TO INSULATE AND SHEET ROCK, EXCEPT THIS AREA |
| 02/11/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) MECHANICAL NOT BLOCKED IN LAUNDRY ROOM 2) NAIL PROTECT WIRSBO LINE FOR FRIDGE LIVING ROOM SIDE 3) NAIL PROTECT WIRSBO LINES IN KITHCEN WITHIN 1 1/2 FROM EDGE OF STUD 4) FIREBLOCK FURRED OUT SPACE IN LIVING ROOM WHERE COPPER LINES COME IN OVER DOUBLE TOP PLATE 5) BLOCK ALL MECHANICAL ON 3 SIDES 6) COMPLY WITH DETAIL 10/DT1 7) DWV'S WATER TEST PASSED, PARTIAL ON PLUMBING UNTIL #2 AND #3 ARE DONE |