Permit: T02CM04267

Parcel: 133232340

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM04267

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
12/11/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
12/10/2002 EXT METAL CLIPS/EXT SHEATHING Not ready for Inspection IVRS - Inspection 0000*
12/09/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999* #5 + A NOT DONE
12/05/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) SEVERAL ROOF OSB PANELS NOT NAILED COMPLETELY ON EAST SIDE. STOPPED ROOFINGS-CHECK ALL 2) ROOF OSB MUST COVER AT LEAST 2 TRUSS BAYS-(3 TRUSSES) OR BE BLOCKED AND NAILED ON 2 NON-TRUSS EDGES 3) A35'S IMPROPERLY INSTALLED ON PATIO ROOF LEDGER 4) PROVIDE PLANS FOR RE-INSPECT 5) ALL NON-CABIN TIED TOP PLATES MUST BE STRAPPED IE.-INTERIOR BAY ANGLES, WEST GARAGE WALL TO WEST HOUSE WALL NOTE FOR INSPECTOR-CHECK PLAN FOR: A) EAST PATIO GIRDER POST B) FRAME AT SOUTH END OF WEST BAY