Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04254
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/21/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* | |
11/20/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) MISSING RED HEADS IN GARAGE (3RD) 2) RUN WIRE TO HALL BATH VENT 3) FIRE BLOCK FRONT ENTRY POP OUTS-2 4) SHIM HEADERS WHERE NEEDED 5) ADD KINGS TO EAST WINDOW 6) REMOVE STAPLES NEAR WIRING 7) MOVE PATH TO MECHANICAL PLATFORM 8) ADHERE TO PLAN RE-KINGS AND TRIMMERS AT 2 SOUTH SIDE G.L. 9) MOVE PEX FROM CAN LIGHTS IN MASTER BATH 10) FHA STRAP REAR GARAGE TOP PLATES AT PLUMBING VENT AND BANG PLATE WIRES AT SAME PLACE |