Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04248

Parcel: 131114810


Addresses:

5680 E 33RD ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/20/2002 FRAMING Approved IVRS - Inspection 0000*
12/19/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*
12/09/2002 FRAMING Denied IVRS - Inspection 0999* 1) NEED WIRE PROTECTION THROUGH METAL FRAMING 2)NEED OUTLETS ON ESAST WALL PER PLAN. 3) NEED H 2.5 CLIPS ON NORTH END OF NEW RAFTERS.
11/22/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) CONFLICT WITH ARCHITECT PLANS AND EXISTING STRUCTURE. EXISTING IS 2 X 6 1/2 FRAMING, ARCHITECT HAS IT LISTED AS 2 X 8 FRAMING