Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM04197
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/26/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
12/20/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SHEAR NAILING SAME AS LAST INSPECTION 2) MISSED ONE ROW OF NAILS ON ROOF DECK MARKED IN BLACK 3) USE 16D COMMONS AT POST TO CONCRETE HARDWARE 4) SHEAR PANEL NAILING AT ROOF DECK USE 8D'S PER DETAIL, PLEASE MARK THE WALL ON THE ROOF DECK 5) SHEAR WALLS EXT. NAIL ALL JOINTS PER SCHEDULE 6) PLAN LEFT ON SITE IS FOR A FLAT ROOF | |
12/18/2002 | EXT METAL CLIPS/EXT SHEATHING | Not ready for Inspection | IVRS - Inspection 0000*/ 1) SHEAR TO BE SPOT NAILED PER SCHEDULE WITH 8D'S NOT STAPLES, IF YOU WANT TO USE STAPLES GET A EQUIVALENCEY CHART 2) NAIL PANELS TO ROOF PER DETAIL 205/54 3) USE 16D COMMONS AT PORCH POST BASE |