Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXCAVATION/LAYOUT REBAR & ZON
| Date |
Description |
Inspector |
Results |
Comments |
| 10/17/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Approved |
IVRS - Inspection 0000* |
| 10/16/2002 |
EXCAVATION/LAYOUT REBAR & ZON |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) BAY WINDOW NOT SHOWN ON STEEL DRAWINGS 2) BEND REBAR #4 UFER OUT OF ENTRY 3) CABLES ARE TOUCHING EARTH IN MAY ARES 4) SECURE H.D.'S 5) DIRT LOT PREPARED FOR BAY WINDOW |