Permit: T02CM04183

Parcel: 136092120

Inspection Status: Approved

Inspection History: ELECTRIC - FINAL

Permit Number - T02CM04183

Inspection Description - ELECTRIC - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
04/23/2003 ELECTRIC - FINAL Approved IVRS - Inspection 0000*
04/22/2003 ELECTRIC - FINAL Denied IVRS - Inspection 0999*/ 1) FINAL WHEN ELECTRIC, MECHANICAL AND PLUMBING COMPLETED 2) ELECTRIC GARAGE OUTLETS MUST BE GFCI PROTECTED. GFCI MASTER BATH ON NORTH SIDE OF SINK SHOWS. HOT/NEUTRAL REVERSE 3) TAPE ALL SINGLE WALL VENT PIPES FOR WATER HEATER AND FURNACES. DO NOT TAPE SINGLE WALL TO DOUBLE WALL JOINTS