Permit: T02CM04182

Parcel: 125150350

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
03/23/2005 FRAMING Approved IVRS - Inspection :*
03/22/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GAS LINE NOT SECURED OR PROTECTED-PLAN CALLS FOR BLACK PIPE
2) INSTALL CLEANOUT FOOT VENT CHI-LOOP
3) TAPE OFF BARE ENDS OF ELECTRIC CONDUCTORS MAIN PANEL
4) GROUND NOT GFCI/CONNECTED
5) SECURE LINE WIRES AWAY FROM HOT PARTS
6) FIREPLACE NOT INSTALLED
03/15/2005 FRAMING Not ready for Inspection IVRS - Inspection :*
1) NEED NOTES FROM ARCHITECT, REF FIREPLACE COMBUSTIBLE MATERIAL CLOSER THAN 2"
2) BANG PLATES ON PIPES AND WIRES
3) ZERO CLEARANCE FIREPLACE TO BE INSTALLED IN NORTH MASTER BEDROOM
4) DIVERTER STUD NOTCHED TO DEEP MASTER SHOWER
5) RUN WIRES THRU, WALL FOR PORCH LIGHTS
6) CONNECT SMOKE DETECTORS S/W GREAT ROOM
7) STIFF LEG CEILING 2 X 4 AT FRONT OFFICE WEST
8) RUN CONDENSATE THRU WALL
9) PEX 12" AWAY FROM LIGHT CANS SOUTH HALL AND KITCHEN
10) CLEANOUT FOR FOOT VENT CHI/LOOP
11) CHECK HEADER SIZE 2ND FLOOR BELOW GIRDER
12) FINISH GAS LINE, NEED PRESSURE TEST
13) H20 HTR NEEDS DIRECT VENT
14) H20 PRESS-OK, DWV TEST OK
03/11/2005 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PROVIDE ALL REVISIONS, SEE INSPECTION DATED 11/17/04
2) ELECTRICAL NOT COMPLETE
3) LEAK AT LAUNDRY
4) NO TEST ON DWV'S