Permit: T02CM04180

Parcel: 134082900

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
06/18/2003 EXT METAL CLIPS/EXT SHEATHING Approved
06/10/2003 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) WHERE IS THE RFI REQUESTED ON 5/12/03 ?
05/12/2003 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*THERE ARE CONFLICTING NOTES ON APPROVED PLAN CONCERNING SHEAR WALL. PAGE 2 CALLS FOR 1/2 C PLYWOOD; PAGE 6 CALLS FOR 1/2" CC OR 3/8" CDX DEPENDING ON WHICH NOTE YOU READ.
PLEASE PROVIDE ENGINEER STAMPED RFI FOR USE OF 3/8" OSB FOR SHEAR PANELS WITH BLOCKING AT ALL EDGES.