Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM04173
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/06/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
11/05/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) LOW VOLTAGE LINES IN CONTACT WITH "B" VENT 2) NO TEST ON DWV 3) AB'S MISSING-REQUIRED WITHIN 12" OF PLATE CUTS 4) GANG LAM HEADERS LAID WITH LAMINATES IN COMPRESSION 5) CONDENSATE LINE NEEDS BANG PLATE AT CORNER 6) STUCCO MESH MUST BE DONE FOR INTERMEDIATE INSPECTIONS | |
11/04/2002 | FRAMING | Not ready for Inspection | IVRS - Inspection 0000* |