Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/06/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/05/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) #3 NOT DONE YET, #2 IN PROGRESS |
| 11/04/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) GARAGE TRUSSES ARE SU325 INSTEAD OF SU265 2) SEE LAST INSPECTION SHEET 1,2,3, AND 4 NOT DONE |
| 11/01/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) STRAP TOP PLATES: WHERE EAST HOUSE WALL MEETS GARAGE EXTENSION WALL, WHERE TOP PLATES MEET BAY GIRDER 2) NO DETAIL FOR NORTH END OF PATIO ROOF CONNECTIONS IE.-GIRDER/LEDGER AND RAFTERS 3) FRONT ENTRY HIP TRUSSES ARE LACKING CONNECTIONS AT BOTH ENDS 4) ROOF NAILING LACKING AT A-8-11 5) PROVIDE TRUSS CALCS |