Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 04/22/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 04/18/2003 |
FRAMING |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GROUND ALL METAL ELECTRIC BOXES 2) SUPPORT 4 SWITCH ELECTRIC BOXES ON 2 ENDS 3) GAS LINE MUST BE ELECTRICALLY BONDED 4) INSTALL BUSHINGS OR ROMEX CLAMPS IN CLEANOUTS 5) PROVIDE DWV WATER TEST ON ALL VENTS PER UPC 712.2 6) NAIL PROTECT LAUNDRY VENT 7) RECESS LIGTH BOX HALL NOT SECURE 8) MAKE UP ALL GROUNDS IN ELECTRIC BOXES 9) SMOKE DETECTORS TO LOW AND IN WRONG LOCATIONS |