Permit: T02CM04077

Parcel: 12003009B


Addresses:

1068 W LINCOLN ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
04/22/2003 FRAMING Approved IVRS - Inspection 0000*
04/18/2003 FRAMING Partial Approval IVRS - Inspection 0000*/ 1) GROUND ALL METAL ELECTRIC BOXES 2) SUPPORT 4 SWITCH ELECTRIC BOXES ON 2 ENDS 3) GAS LINE MUST BE ELECTRICALLY BONDED 4) INSTALL BUSHINGS OR ROMEX CLAMPS IN CLEANOUTS 5) PROVIDE DWV WATER TEST ON ALL VENTS PER UPC 712.2 6) NAIL PROTECT LAUNDRY VENT 7) RECESS LIGTH BOX HALL NOT SECURE 8) MAKE UP ALL GROUNDS IN ELECTRIC BOXES 9) SMOKE DETECTORS TO LOW AND IN WRONG LOCATIONS