Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04077

Parcel: 12003009B


Addresses:

1068 W LINCOLN ST

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Date Description Inspector Results Comments
12/02/2002 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
11/20/2002 REINFORCED MASONRY PRE-GROUT Partial Approval 1) OK TO GROUT 2ND LIFT AND BOND BEAM
11/13/2002 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) OK TO GROUT 1ST LIFT AND CONTINUE WITH 2ND LIFT, CALL FOR A PRE-GROUT AND BOND BEAM INSPECTION PRIOR TO GROUTING 2ND LIFT