Permit: T02CM04069

Parcel: 111072750

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
12/04/2002 FRAMING Approved IVRS - Inspection 0000*
11/22/2002 FRAMING Denied IVRS - Inspection 0950*/ 1) CANNOT APPROVE INTEMEDIATE ITEMS UNTIL EXTERIOR OF BUILDING IS LATHED 2) NAIL PROTECT ALL WIRES AND PLUMBING WITHIN 1 1/4" OF STUD SURFACES 3) DRAFT STOP FURNACE PLATFORM 4) PROVIDE PLUMBING DWV WATER TEST PER UPC SECTION 712.2 5) ALL WIRES MUST TERMINATE IN APPROVED ELECTRIC BOXES 6) EDGE NAILING OF WIRES NOT ALLOWED 7) NO OTHER OUTLETS ALLOWED ON BATHROOM GFCI CIRCUIT 8) SECURE ALL ROMEX CLAMPS 9) BEDROOM AND ROOM LEADING TO BEDROOM REQUIRE SMOKE DETECTORS