Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
| Date |
Description |
Inspector |
Results |
Comments |
| 11/12/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Approved |
IVRS - Inspection 0000* |
| 11/07/2002 |
EXT METAL CLIPS/EXT SHEATHING |
|
Denied |
IVRS - Inspection 0999*/ 1) BANG PLATES MISSING 2) EXPOSE FRONT ENTRY COLUMNS AT BASE 3) 2 NAILS REQUIRED AT TOP AND BOTTOM PLATE AT WALL BRACES 4) NAIL SHEAR TRUSS W/#8 AT 6" ON CENTER AT OSB 5) HAVE ENGINEER OF RECORD CLARIFY E.N. AT DETAIL DT1/10 |