Permit: T02CM04049

Parcel: 141012550

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM04049

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/30/2002 FRAMING Approved IVRS - Inspection 0000*
12/27/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SEE LAST INSPECTION
12/23/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) SHEAR NAILERS NOT INSTALLED, MARKED ON FLOOR
12/20/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) CAN'T CHECK TOP NAILER FOR DRYWALL SHEAR 2) P.T. PLANS WAS ALL THAT WAS LEFT FOR INSPECTION
12/12/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) NEED BACKING AROUND TUB FOR DRYWALL 2) BLOCK AND STRAP SUPPLY LINES FOR LAVS 3) NEED 2ND GFCI IN BATHROOM 4) INSTALL CRIPPLE STUD AT PLENUM IN CLOSED 5) BLOCK RETURN AIR PLENUM BOTH SIDES 6) BACKING FOR DRYWALL NORTH EDGE OF TUB EAST END OF TUB 7) INSULATE BEHIND TUB 8) NEED TOP PLATE NADLERS FOR ALL SHEARWALLS DRYWALL SW1 AND SW2 9) GAS PRESSURE TEST OK