Permit: T02CM04040

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Permit Number - T02CM04040

Inspection Description - PLUMBING - ROUGH, SOIL

Inspection Status - Approved

Date Description Inspector Results Comments
02/26/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*SOIL WATER TEST FOR UNITS 1,2,3, OK
2.) AIR PRESSURE TEST FOR UNITS 4,5,6,7 IS OK
3.) OK TO BACKFILL TRENCH.
02/25/2003 PLUMBING - ROUGH, SOIL Denied 1.) MUST PROVIDE AIR TEST FOR WASTE & VENT SYSTEM FOR UNITS #4,5,6,7 ONLY 5LBS MIN
2.) MUST EXPOSE ROUGH PLBG. FOR UNITS #1,2,3 AND PROVIDE WATER TEST.
3.) MUST FLUSH BUT EXSISTING ROUGH PLBG. FOR ENTIRE BLDG. 1 ALL UNITS.