Permit: T02CM04035

Parcel: 134090010

Inspection Status: Approved

Inspection History: REINFORCED MASONRY PRE-GROUT

Permit Number - T02CM04035

Inspection Description - REINFORCED MASONRY PRE-GROUT

Inspection Status - Approved

Date Description Inspector Results Comments
08/01/2003 REINFORCED MASONRY PRE-GROUT Approved IVRS - Inspection 0000*
07/30/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* 12' 8" AFF
07/29/2003 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000* CANCELLED BY CONTR.
07/28/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* 8' AFF EAST WALL MUST HAVE KEDGER BOLTS AND PA STRAPS INSTALLED BEFORE INSP
07/25/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000* 8' AFF
07/24/2003 REINFORCED MASONRY PRE-GROUT Not ready for Inspection IVRS - Inspection 0000*/ 1) SITE LOCKED 2:50 PM
07/23/2003 REINFORCED MASONRY PRE-GROUT Partial Approval IVRS - Inspection 0000*/ 1) 1ST LIFT OK
07/22/2003 REINFORCED MASONRY PRE-GROUT Denied IVRS - Inspection 0999*/ 1) SEE GSN'S ON S101 "LAP SPLICES ARE 48 BAR DIAMETERS FOR GRADE 60 STEEL (30" FOR #5). THIS NEEDS TO BE INCREASED. 30 PERCENT WHEN 2 BARS ARE IN SAME CELL (39" FROM #5)