Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
| Date |
Description |
Inspector |
Results |
Comments |
| 07/23/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Approved |
IVRS - Inspection 0000* |
| 07/22/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) ALL BUT IN FILL WHERE VEHICLES COME THROUGH |
| 07/21/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Denied |
IVRS - Inspection 0999*/ 1) PER GSN PP S101 YOU MAY NOT HAVE A REBAR SPLICE (HORIZONTAL) WITHIN 8' OF A CONTROL JOINT |
| 07/18/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) TOPPING OUT 232, 234 AND 235, NOT COMPLETE ENOUGH FOR INSPECTION 2) SMALL COLUMNS AT INTERIOR COURT YARD OK TO 4' |
| 07/17/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) MAIN BLDG. TAPED OUT EXCEPT 234, 235, 232. 2) ROOMS 232, 234, 235 @ 14' AFF. 3) NEED ENGINEER REPORT FOR BOND BEAM @ LINTEL? INSTEAD OF ABOVE LINTEL PER 207/5601 - SEE SPECIAL INSPECTION NOTES DATED 7/9/03. |
| 07/16/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) GROUTED W/O INSPECTION-NO SPECIAL INSP REPORT ON SITE 2) DAILY FIELD REPORTS ARE REQUIRED TO BE ON SITE, PLEASE TALK TO YOUR SPECIAL INSPECTOR. THE CITY OF TUCSON PERFORMS INSPECTIONS BETWEEN 7:00 AM AND 3:30 PM. IT IS 1:37 PM RIGHT NOW BUT YOUR SITE IS LOCKED |
| 07/15/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 13' HIGH NORTH WALLS; NEED VERTS IN OTHER HIGH WALLS |
| 07/14/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 4TH LIFT AT ED. BLDG |
| 07/11/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 9'-6" AFF-CARE MUST BE TAKEN WHILE GROUTING TO ENSURE 30" ? SPLICE ON VERTICALS |
| 07/10/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) VARIOUS ELEVATIONS INTERIOR AND WEST WALLS |
| 07/09/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* TOP OF ALL EXTERIOR 9'-8'' WALL |
| 07/08/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*1) VERTS N CELL BELOW B2 MUST EXTEND TO ??SENT SE DETAIL 208. 2) BOND BEAM REQUIRES 2 EACH #5 BARS AT EACH FACE UNDER BEAM NOT BOND? AT ONE FACE 3) 8' AFF " LOW WALL AREA" AND SW CORNER. |
| 07/07/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 9' AFF NSE EXTERIOR 4' AFF INTERIOR EXCEPT MIDDLE SECTION ALONG LINE 12 |
| 07/03/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000* |
| 07/01/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 4' AFF LAUNDRY AND STORAGE AREAS NORTH END |
| 06/30/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
IVRS - Inspection 0000*/ 1) 4' EAST WALL AND NORTH RETURN 2) MINIMUM ? SPLICE FOR #5 IS 30", WHEN 2 BARS IN CELL IT'S 39" |
| 06/26/2003 |
REINFORCED MASONRY PRE-GROUT |
|
Partial Approval |
1) PRE-GROUT: A) 4' AFF SOUTH EXTERIOR WALL B) 4' AFF WEST RETURN WALL |