Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM04020

Parcel: 141147100

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
09/19/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/18/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP ENTRY GIRDER TO COLUMN 4 X 4
09/17/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) STRAP FRONT GIRDER TO COLUMN, INSTALL TOP STUD CLIPS AND STRAP TRUSS TO COLUMN 2) STRAP SOUTH GABLE TRUSS TO WALL 3) CLIP SOUTH BAY RAFTERS 4) H2.5 PATIO RAFTERS 5) FINISH NORTH PATIO DOOR AND H.D.'S 6) STRAP NORTH GABLE TRUSS TO SHORT COMMON RAFTER AND RAFTER DOWN TO TOP PLATES