Permit: T02CM03954

Parcel: 13821019K


Addresses:

135 W CORONA RD

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
07/14/2003 PLUMBING - FINAL Approved IVRS - Inspection 0000*
07/11/2003 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
1)CUT SEWER CLEAN OUT TO GRADE
2)COMPLETE GRADING
3)GAS FLEX CANNOT ENTER CABINET FURNACE (HARD PIPE REQUIRED)
4)SEAL AROUND DRYER VENT EXTERIOR
5)TURN WATER HEATER PTR TERMINATION TO POINT DOWNWARD
6)PAINT EXPOSED VTRS
7)POST PERMANENT ADDRESS ON HOUSE
07/10/2003 PLUMBING - FINAL Denied IVRS - Inspection 0999* 1) UNCOVER &WATER TEST SEWER FROM CLEANOUT TO CONNECTION AT P.L. IN FRONT. 2) PAINT EXPOSED PLB VENT ON ROOF. 3) LOCKED STOPPED INSP. 4) POST ADDRESS #'S ON HOUSE