Permit: T02CM03945

Parcel: 141304930

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM03945

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/18/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/17/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROOF OSB PIECES, THAT COVER ONLY ONE TRUSS BAY, MUST BE BLOCKED AND NAILED OFF 2) 2ND FLOOR SHEARWALL OSB IS NOT NAILED AT REAR AND AT NORTHWEST CORNER 3) STRAP TOP PLATES AT ALL NON-CABIN TIED EXTERIOR INTERSECTIONS 4) STRAP ENTRY GABLE TRUSS DOWN 5) WEST WINDOW OPENING NEEDS DOUBLE TRIMMERS AND EAST WINDOWS THAR ARE 5' 6) H2.5 PATIO RAFTERS 7) A-35 OUTSIDE PATIO RAFTERS 8) NEED RED HEAD AT REAR END OF GARGE EAST PLATE