Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: EXT METAL CLIPS/EXT SHEATHING
Permit Number - T02CM03945
Inspection Description - EXT METAL CLIPS/EXT SHEATHING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/18/2002 | EXT METAL CLIPS/EXT SHEATHING | Approved | IVRS - Inspection 0000* | |
10/17/2002 | EXT METAL CLIPS/EXT SHEATHING | Denied | IVRS - Inspection 0999*/ 1) ROOF OSB PIECES, THAT COVER ONLY ONE TRUSS BAY, MUST BE BLOCKED AND NAILED OFF 2) 2ND FLOOR SHEARWALL OSB IS NOT NAILED AT REAR AND AT NORTHWEST CORNER 3) STRAP TOP PLATES AT ALL NON-CABIN TIED EXTERIOR INTERSECTIONS 4) STRAP ENTRY GABLE TRUSS DOWN 5) WEST WINDOW OPENING NEEDS DOUBLE TRIMMERS AND EAST WINDOWS THAR ARE 5' 6) H2.5 PATIO RAFTERS 7) A-35 OUTSIDE PATIO RAFTERS 8) NEED RED HEAD AT REAR END OF GARGE EAST PLATE |