Permit: T02CM03935

Parcel: 13312006M

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
10/09/2002 PLUMBING - INTERMEDIATE Approved IVRS - Inspection 0000* 1) SOIL WATER TEST ON WASTE & VENT SYSTEM IS OK 2) OVERHEAD WATER DISTRIBUTION IS OK 3) OK FOR DRYWALL 4) NOTE: MUST STUB OUT CONDENSATE DRAIN TO LAVATORY TAIL PC ONLY
10/03/2002 PLUMBING - INTERMEDIATE Denied IVRS - Inspection 0999*1.) NO WATER TEST THRU ROOF ON ABS DWV. 2.) A SINK IS NOT AN APPROVED LOCATION FOR A CONDENSATE DRAIN.