Permit: T02CM03926

Parcel: 133232540

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T02CM03926

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
12/27/2002 BUILDING - FINAL Approved IVRS - Inspection 0000*
12/26/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) HOME LOCKED
12/24/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
12/23/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) NEED BACKPLOW VALVE ON WEST HOSE BIB 2) CORRECT NEUTRALS WHERE STRIPPED FOR LUGS-COPPER BADLY DAMAGED
12/20/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*
12/19/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*/ 1) COLOR HOT WHITES AND STRIP INSULATION FROM UNDER NEUTRAL LUGS 2) NEED BACKFLOW VALVE ON HOSE BIBS WEST 3) CORRECT NEG. PITCH ON TPR DRAIN 4) NO POWER TO BATH GFI'S 5) CLEAN LOOSE FILL OUT OF SECONDARY CONDENSATE PAN NOTE: DISHWASHER NOT IN YET