Permit: T02CM03903

Parcel: 205661310

Inspection Status: Approved

Inspection History: BUILDING - FINAL

Date Description Inspector Results Comments
04/28/2005 BUILDING - FINAL Approved IVRS - Inspection :*
1) THIS IS AN INSPECTION FOR FINALS ONLY
2) COMPLETED WITHOUT FRAMING INSPECTION
04/22/2005 BUILDING - FINAL Partial Approval IVRS - Inspection :*
1) SPRINKLER INSPECTION
2) KITCHEN AND GARAGE GFCI NOT PROTECTED
03/30/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :* CLEAR FOR CDTS
1) CAP ALL GTAS VALVES. 2) TIGHTEN OUTLETS LAUNDRY 3) NEED TO SEE TUB DRAIN, WITH H20 TEST. 4) NEED PLAN CHECK DRYWALL IN GARAGE. 5) KIT C.O. 6) D.W.V H20 TEST 7) NEED FROM LAST INSP # 2,3,10,12, 14, 17, 18 8) CHECK INSIDE AT DIVERTER FOR SOIL LEAKS.
03/29/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :* CANCEL & RESCHEDULE BY HOME OWNER
03/11/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NEED HOUSE ADDRESS
2) CLEANOUTS FOR FIXTURES
3) CONNECT ROMEX FOR ROOF EXHAUST FAN
4) RAISE DISPOSAL DISCHARGE LINE
5) NEED GAS, H20 BOND
6) NEED POWER ON FOR POWER CHECK
7) INSPECTION FOR PLUMBING BEDROOM #3 AND LAUNDRY, DIVERTER VALVE
8) NEED PRESSURE TEST ON H20 LINES
9) SCUPPERS TO BE 6" DIAMETER
10) NEED LANDSCAPE INSPECTION SIGNED OFF
11) OUTLET COVERS
12) NEED SEPTIC INSPECTION
13) INSP. H20 LINE
14) SPRINKLER SYSTEM INSP
15) VERIFY METER SIZE
16) OUTLET COVERS
17) GARAGE FIRE WALL
18) CHECK HOT H20
03/07/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) NEED FIRE CAULK IN TIRE/PLACE LOG LITER
2) WILL NEED TO CONFIR WITH MY SUPER/INSP. REFLECTIONS
3) CONNECT KITCHEN EXHAUST FAN ON ROOF
4) NO DETAIL FOR SCUPPERS
02/07/2005 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*
1) ALL INSPECTIONS NOT SIGNED OFF
2) CHECK INTEGRAL BY PASS AT P.R.V.
3) NEED POWER ON
4) EXTEND COMBUSTION DUCT DOWN 12" FROM FLOOR
5) COVER FOR COMB/RELIEF DUCTS
6) HOOK UP KITCHEN ROOF FAN SCUPPER OVER FLOWS TO GO SEPERATE FROM, PRIMARY LINE
7) NO RECORDS ON SITE FROM PREVIOUS INSPECTIONS
05/07/2004 BUILDING - FINAL Not ready for Inspection IVRS - Inspection :*/ 1) WATER SERVICE STILL LEAKS