Inspection History: FRAMING
Permit Number - T02CM03884
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/11/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/10/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) JOIST HANGERS ARE NOT AS SPECIFIED ON PLAN-HUS 26 REQUIRED NEXT FAILURE WILL INCUR RE-FEE | |
10/09/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) NO WATER FOR DWV TEST-LEAK IN NORTH BATH 2) INSULATE AT YOUR RISK OF DWV FAILURE | |
10/08/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) DWV TEST FAILED 2) PLAN SPECS HUS26 HANGERS AT ALL GIRDER TRUSSES 3) GIRDERS REQUIRE 3-2 X 6 POST EACH END SEE FRAMING PLAN | |
09/27/2002 | FRAMING | Not ready for Inspection |