Permit: T02CM03884

Parcel: 141302440

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM03884

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
10/02/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
09/30/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) ROOF OSB NEEDS TO BE NAILED OFF, ON AND UNDER BOTH SMALL FRONT HIP ROOFS 2) STRAP SOUTHEAST TOP PLATES THAT AREN'T CABIN TIED 3) STRAP NON CABIN TIED TOP PLATES AND HEADER IN FRONT ENTRY AREA