Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM03866

Parcel: 133233010


Addresses:

411 N BROOK PARK DR


Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Permit Number - T02CM03866

Inspection Description - EXT METAL CLIPS/EXT SHEATHING

Inspection Status - Approved

Date Description Inspector Results Comments
11/04/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/28/2002 EXT METAL CLIPS/EXT SHEATHING Partial Approval IVRS - Inspection 0000*/ 1) PLAN CALLS FOR B.C. 450'S. YOU HAVE LPI 300 2) MISSING WINDBRACING EACH CORNER AND 25' ON CENTER 3) ROOF SQUEAKY CRICKET EAST BEDROOM 4) MISSING H2.5'S AT PARAPET TO LEDGERS