Permit: T02CM03862

Parcel: 12101103E

Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T02CM03862

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
11/26/2002 PLUMBING - FINAL Approved IVRS - Inspection 0000*
11/25/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*
11/22/2002 PLUMBING - FINAL Denied IVRS - Inspection 0999*1.) BACKFLOW PREVENTER REQUIRES A DISCHARGE DRAIN.
2.) BACKFLOW PREVENTER MUST BE INSTALLED SO THAT TESTER CAN HAVE ACCESS TO PARTS.
11/15/2002 PLUMBING - FINAL Partial Approval IVRS - Inspection 0000*
1.) PBLG FINAL IS OK 2.) NOTE: WILL REQUIRE A TRAP PRIMER & BACKFLOW PREVENTER #009 FOR WATER SUPPLY FOR FILM PROCESSOR.
3.) BACKFLOW PREVENTER MUST BE TESTED & CERTIFIED PRIOR TO FINAL INSPECTION.
11/14/2002 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection 0000*
11/12/2002 PLUMBING - FINAL Not ready for Inspection