Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03857
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/26/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
09/24/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) SUPPORT PEX IN GARAGE CEILING 2) BANG PLATE PLUMBING AT TOP PLATES IN LAUNDRY 3) SUPPORT WIRES ABOVE KITCHEN STOVE/FRIDGE 4) STRAP LAV HORIZONTAL DRAIN IN 1ST FLOOR CEILING-SOUTH WALL 5) TAPE DUCT TEARS IN KITCHEN CEILING AND DINING CEILING AND ABOVE CEILING 6) BANG PLATE WIRES AT KITCHEN SINK 7) CORRECT FIRE BLOCKING IN PASS THROUGH CAVITY 8) NEED DWV TEST 9) CORRECT DUCT CRIMP AT TOP OF STAIRS 10) FAN WIRING IN HALL BATH NEEDS MOUNTING IN BOX 11) FIRE STOP WALL CHASE IN NORTHWEST BED 12) NAIL OFF FHA STRAPS ABOVE MASTER TUB |