Permit: T02CM03854

Parcel: 13809007G


Addresses:

436 W VALENCIA RD


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T02CM03854

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
09/05/2002 BUILDING - FINAL Approved
08/21/2002 BUILDING - FINAL Partial Approval IVRS - Inspection 0000*ADA PARKING SHOWN ON SITE PLAN NEXT TO TENANT SPACE DOES NOT HAVE AN ACCESS RAMP. THERE IS NO OTHER HC PARKING WITHIN 100' AT OF TENANT ENTRANCE. 2.) SPACE DOES NOT HAVE A FIRE RATED WALL PER PLAN DAVID MANN HAS APPROVED THE DELETION OF THE WALL PER IBC 302.3.2. 3.) ADA BATHROOM ON PLAN DID NOT MEET REQUIREMENT SO AN A.D.A. BATH HAS BEEN PROVIDED @ NM CORNER OF SPACE. 4.) OTHER EGRESS ISSUES ARE OK.
08/20/2002 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*1.) BATHROOM SINK IN NW BATHROOM RAISED. 2.) COVE MOLDING IN BATHROOMS INSTALLED. 3.) ALL OTHER ITEMS FROM YESTERDAY MUST BE ADDRESSED BEFORE RE-CALLING INSPECTION. AND 4.) INSTALL NO KNOWLEDGE HARDWARE ON ADA. BATHROOM DOOR. 5.) INSTALL HC ACCESS SIGNAGE ON ADA BATHROOM. 6.) HANDICAP PARKING @ FRONT DOES NOT HAVE AN ACCESS RAMP.
08/19/2002 BUILDING - FINAL Denied IVRS - Inspection 0999*1.) NEED ADA HARDWARE ON ADA BATHROOM DOOR. 2.) INSULATE HOT WATER LINE & DRAIN LINES IN ADA BATHROOM. 3.) BATHROOM LISTED ON PLANS AS ADA DOES NOT HAVE THE 60" TURNING RADIUS REQUIRED. REAR BATHROOM ON WEST SIDE MAY BE CONVERTD TO ADA BY INSTALLING PROPER SINK FIXTURES AND RAISING SINK SO YOU HAVE 27"-29" CLEARANCE UNDERNEATH WITH RIM OF SINK 34" HIGH MAXIMUM. 4.) WATEPROOF BASE MOLDING REQUIRED IN BATHROOMS TO EXTEND 6" ABOVE FLOOR. 5.) WEST WALL REQUIRED TO BE 2 HR. FIRE RATE PER IBC 302.3.3.
A.) THIS REQUIRES A 2 HOURS ASSEMBLY 2 LAYERS 5.8 LAYER SHEETROCK ON EACH SIDE OF METAL STUD WALL WITH ALL PENETRATIONS PROPERLY FIRE STOPPED.
B.) ALL DATA CABLE TERMINATIONS IN FRIE WALL SHOULD BE IN LISTED BOX.