Inspection History Details
Inspection Status: Approved
Inspection History: FRAMING
Permit Number - T02CM03844
Inspection Description - FRAMING
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/24/2002 | FRAMING | Approved | IVRS - Inspection 0000* | |
10/21/2002 | FRAMING | Denied | IVRS - Inspection 0999*/ 1) RED HEAD ANCHOR BOLTS REQUIRED WITHIN 12" OR PLATE ENDS 2) RED HEADS A. B.'S LOOSE 3) NAIL IN DRYER DUCT. REPLACE DUCT 4) TJI HANGERS NOT NAILED 5) SAN T' CRACKED MASTER BATH 6) FIREPLACE VENT NOT UPPORTED 6) WIRES NOT MADE UP THROUGHOUT 7) FIREPLACE VENT NOT COMPLETE |