Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: T02CM03803

Parcel: 137314130

Inspection Status: Approved

Inspection History: EXT METAL CLIPS/EXT SHEATHING

Date Description Inspector Results Comments
10/15/2002 EXT METAL CLIPS/EXT SHEATHING Approved IVRS - Inspection 0000*
10/14/2002 EXT METAL CLIPS/EXT SHEATHING Denied IVRS - Inspection 0999*/ 1) PA STRAPS INCOMPLETE 2) INSTALL BANG PLATES EXTERIOR PLATES AT PLUMBING PENETRATIONS 3) 2 NAILS TOP AND BOTTOM WIND BRACING 4) WIND BRACING MAXIMUM 25' OF RUN AND (ALL EACH) CORNER BOTH WAYS 5) STOPPED INSPECTION