Inspection Status: Approved
Inspection History: FRAMING
| Date |
Description |
Inspector |
Results |
Comments |
| 02/27/2003 |
FRAMING |
|
Approved |
IVRS - Inspection 0000* |
| 02/24/2003 |
FRAMING |
|
Denied |
IVRS - Inspection 0999*/ 1) WATER TEST REQUIRED ON PLUMBING TOP OUT 2) FIRE STOP CHIMNEY CHASE AT CEILING 3) NEED APPROVED CROSS SECTION OF GARAGE SHOWING AS BUILT AT ROOF FRAME 4) SHEARWALL NOT NAILED PER SCHEDULE #8 NAILS REQUIRED 5) NOT COMPLETE NAIL MESH 6" ON CENTER TOP AND BOTTOM, CHECK THRU-OUT 6) 33-6" X 18" ROOF VENTS ?? |