Permit: T02CM03792

Parcel: 10311037J


Addresses:

3075 W NEOSHA ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/27/2003 FRAMING Approved IVRS - Inspection 0000*
02/24/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) WATER TEST REQUIRED ON PLUMBING TOP OUT 2) FIRE STOP CHIMNEY CHASE AT CEILING 3) NEED APPROVED CROSS SECTION OF GARAGE SHOWING AS BUILT AT ROOF FRAME 4) SHEARWALL NOT NAILED PER SCHEDULE #8 NAILS REQUIRED 5) NOT COMPLETE NAIL MESH 6" ON CENTER TOP AND BOTTOM, CHECK THRU-OUT 6) 33-6" X 18" ROOF VENTS ??
02/07/2003 FRAMING Denied IVRS - Inspection 0999*/ 1) ELECTRICAL NOT COMPLETE 2) NO TEST ON DWV'S 3) LATH HOUSE BEFORE INTERMEDIATE INSPECTIONS 4) CALL BACK WHEN ALL TRADES ARE COMPLETE