Permit: T02CM03775

Parcel: 141013130

Inspection Status: Approved

Inspection History: FRAMING

Permit Number - T02CM03775

Inspection Description - FRAMING

Inspection Status - Approved

Date Description Inspector Results Comments
12/12/2002 FRAMING Approved IVRS - Inspection 0000*
12/09/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) DWV FAILED WATER TEST 2) CHECK FRAMING AT MECHANICAL ROOM 3) MECHANICAL NOT BLOCKED 3 SIDES AT SOUTHWEST BEDROOM AND MECHANICAL ROOM 4) LOOSE RED HEADS THROUGHOUT 5) FIRE BLOCK MISSING AT MASTER BATH 6) NAIL PROTECT DRYER VENT 7) STOPPED INSPECTION, HAVE SUPERVISOR INSPECT HOUSE BEFORE RECALLING
12/05/2002 FRAMING Not ready for Inspection IVRS - Inspection 0000*/ 1) VENT BLOCK 2) CHANGE OUT 8D'S IN THA HANGERS TO 10D'S 3) CHECK SOFT WATER LOOP FOR PRESSURE TEST 3) ELECTRIC OUTLET LOOSE 3) WHAT'S THE AMPERAGE OF THE FURNACE IF ELECTRIC IF GAS NEED 4 FLUE
12/03/2002 FRAMING Denied IVRS - Inspection 0999*/ 1) CHECK FOR FIRE BLOCKS 2) CHECK FOR LEAKS AT TUBS 3) CHECK MECHANICAL REGISTER BLOCKING