Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T02CM03774

Parcel: 141016510


Addresses:

5100 S RENEWAL LN


Inspection Status: Approved

Inspection History: BUILDING - FINAL

Permit Number - T02CM03774

Inspection Description - BUILDING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
03/26/2003 BUILDING - FINAL Approved IVRS - Inspection 0000*
03/25/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) MECHANICAL ON ROOF NOT APPROVED
03/24/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) UNIT NOT LABELED FOR OVER CURRENT PORTECTION 2) NO VENT FOR CONDENSATE LINE 3) CONNECTION AND SEAL TIGHT TO PVC 4) TO HOLES FOR CONVIENENCE OUTLET NOT PLUGGED
03/20/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) 3RD TIME ROOF ITEMS STILL NOT DONE
02/27/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) ALL ITEMS FROM LAST INSPECTION ON ROOF NOT COMPLETE
02/26/2003 BUILDING - FINAL Not ready for Inspection IVRS - Inspection 0000*/ 1) ROOF MISSING TO T-TOPS, DRYER, AND MAKE UP AIR 2) NEED VENT ON CONDENSATE, OR FIND LABELING FOR INTERNAL VENT 3) PUT FURNACE CONTROL WIRE IN CONDUIT, AND INSTALL ROOF JACK 4) TWO HOLES NOT PLUGGED IN CONVIENENCE OUTLET 5) LABEL HEAT STRIP 6) CHECK PLAN FOR WALL OUTLET IN MASTERBED ALCOVE BELOW LIGHT BAR 7) FIND REST FOR GFCI IN GARAGE EXT.