Permit: T02CM03764

Parcel: 138041140


Addresses:

927 W CALLE CASTILE

Inspection Status: Approved

Inspection History: PLUMBING - ROUGH, SOIL

Date Description Inspector Results Comments
03/26/2003 PLUMBING - ROUGH, SOIL Approved IVRS - Inspection 0000*
03/21/2003 PLUMBING - ROUGH, SOIL Denied IVRS - Inspection 0999*/ 1) SANITARY "T" FITTING AT CONNECTION TO EXISTING SEWER NOT ALLOWED 2) SANITARY "T" FITTINGS NOT ALLOWED FOR USE AS DRAIN FITTINGS MUST BE DIRECTIONAL FITTINGS 3) SHORT RADIUS BENDS NOT ALLOWED IN HORIZONTAL DRAINS 4) PRVOIDE A 10 FOOT HIGH DWV WATER TEST ON COMPLETE SYSTEM PER UPC PARAGRAPH 712.2 5) TUB TRAP MUST BE INSTALLED