Inspection Status: Approved
Inspection History: ELECTRIC - UNDERGROUND
| Date |
Description |
Inspector |
Results |
Comments |
| 06/24/2003 |
ELECTRIC - UNDERGROUND |
|
Approved |
IVRS - Inspection 0000* |
| 06/19/2003 |
ELECTRIC - UNDERGROUND |
|
Not ready for Inspection |
IVRS - Inspection 0000*/ 1) BOND ALL METAL ELECTRIC BOXES 2) FURNACE VENT MUST BE CLASS "B" VENT TO (DOUBLE WALL) WITH 1" CLEARANCE TO COMBUSTIBLES 3) BOND GAS LINE IN EXPOSED LOCATION 4) SEPARATE HOUSE MUST HAVE TWO 8' GROUND RODS 6' APART CONNECTED TO SUBPANEL WITH CONTINOUS #4 GROUND 5) BLOCK ALL MECHANICAL DUCT BOOTS ON 3 SIDES 6) BLOCK FURNACE PLATFORM ALL AROUND 7) PROVIDE 22" X 30" ATTIC ACCESS 8) HOUSE GAS TEST OK, OUTSIDE NOT READY |