Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date |
Description |
Inspector |
Results |
Comments |
| 09/04/2003 |
BUILDING - FINAL |
|
Approved |
IVRS - Inspection 0000* |
| 08/22/2003 |
BUILDING - FINAL |
|
Denied |
IVRS - Inspection 0999*/ 1) TRIM CLEANOUTS TO GRADE AND INSTALL THREADED CAPS 2) WATER HEATER SINGLE WALL VENT REQUIRES 6" TO WOOD 3) OUTSIDE HOSE BIBS REQUIRE NON-REMOVABLE ANTI-SIPHON VALVES 4) KITCHEN COUNTER AND SINKS MUST BE INSTALLED 5) ALL KITCHEN OUT LETS EXCEPT FRIG MUST BE GFCI PROTECTED 6) REMOVE TAPE FROM FURNACE SINGLE WALL TO DOUBLE WALL CONNECTION 7) 14 GAUGE WIRE NOT ALLOWED ON 20 AMP BREAKER |