Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
Permit Number - T02CM03758
Inspection Description - BUILDING - FINAL
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2003 | BUILDING - FINAL | Approved | IVRS - Inspection 0000* | |
| 09/30/2003 | BUILDING - FINAL | Denied | IVRS - Inspection 0999*/ 1) CUT CLEANOUTS TO GRADE AND INSTALL THREADED CAPS 2) KITCHEN REQUIRES 2 CIRCUITS/MUST BE GFCI PROTECTED 3) DISHWASHER DRAIN MUST LOOP UP TO BOTTOM OF COUNTER 4) INSTALL DOOR BELL TRANSFORMER OR CAP BOX 5) SMOKE DETECTORS DON'T CALL EACH OTHER 6) COVER OPENINGS IN ELECTRIC PANEL DEAD FRONT |